EXCEN NRG 3K ATEX & IECEx UPS System
EXCEN NRG 3K ATEX IECEx UPS system for hazardous areas with stainless steel battery enclosureEXCEN NRG 3K ATEX UPS system dimensional drawing front, top and side views
Excen · Authorised partner

EXCEN NRG 3K ATEX & IECEx UPS System

The EXCEN NRG 3K is an ATEX & IECEx certified UPS system providing reliable backup power for hazardous areas (Zone 1, Zone 2, Zone 21 and Zone 22).

Certification & ratingVerified
Standard PowerUp to 6 kVA
Input150-265 Vac / 50-140 Vac, 45-65 Hz
OutputPure sine wave 230 Vac (±2%) / 120 Vac
Output Frequency50 Hz ±0.05%, 45-65 Hz programmable
  • Genuine certified equipment sourced directly through Daly Middle East.
  • Full manufacturer support and warranty.
Overview

About this product

The EXCEN NRG 3K is an ATEX & IECEx certified UPS system providing reliable backup power for hazardous areas (Zone 1, Zone 2, Zone 21 and Zone 22). Manufactured in Italy by EXCEN S.R.L., it delivers continuous, stable power in a standard configuration of up to 6 kVA (see the thermal derating table), with a fast transfer time of 15 ms or less. Daly Middle East is the authorized distributor of EXCEN ATEX products across the UAE, Saudi Arabia, Kuwait, Qatar, Bahrain and Oman.

The NRG 3K is particularly suited to instrumentation, control and auxiliary systems that need dependable backup during power outages or mains fluctuations. Its IP66 enclosure is highly rugged and operates reliably across a wide ambient temperature range. The system is mounted on a robust frame with a modular design that adapts to your application, and a glass inspection window gives immediate visual confirmation of system status and alarms.

It is supplied as a ready-to-install solution, complete with an ATEX & IECEx certified battery in a stainless steel enclosure (AGM, GEL or NiCd technology) for long service life and high reliability. A dedicated battery breaker between the UPS and the battery maximizes safety and simplifies maintenance.


Technical Specifications

Parameter Value
Input voltage and frequency 150 to 265 Vac / 50 to 140 Vac, 45 to 65 Hz
Output voltage Pure sine wave 230 Vac (±2%) / 120 Vac
Output frequency 50 Hz ±0.05% (crystal controlled), 45–65 Hz programmable
Transfer time ≤ 15 ms
Protection rating IP66
Hazardous area zones Zone 1, Zone 2, Zone 21 and Zone 22
Standard power Up to 6 kVA (refer to thermal derating)
Battery technology AGM, GEL or NiCd in ATEX & IECEx certified stainless steel enclosure

Customized options with different power and input/output ratings are available upon request.


Thermal Derating — Maximum Output Power vs. Ambient Temperature

Operation above the temperatures shown is reduced or not recommended.

Rated output (VA) Max ambient temperature
500 up to 55°C
1,000 up to 50°C
1,500 up to 48°C
2,000 up to 45°C
2,500 up to 42°C
3,000 up to 40°C
5,000 up to 35°C
6,000 up to 30°C

Battery Backup Autonomy

Estimated backup time with a 48 VDC, 205 Ah battery bank at 25°C.

Rated load (VA) Estimated backup time
500 15 h 00 min
1,000 7 h 30 min
1,500 4 h 30 min
2,000 3 h 15 min
2,500 2 h 30 min
3,000 2 h 00 min
5,000 1 h 00 min
6,000 0 h 45 min

Actual backup time may vary depending on inverter cut-off voltage threshold, battery age, temperature and real efficiency.


Typical Applications

  • Oil & Gas facilities (onshore and offshore platforms)
  • Chemical and petrochemical plants
  • Refineries and process industries
  • Emergency shutdown systems (ESD)
  • Fire & gas detection systems
  • Power distribution and automation systems
  • Critical backup for safety-related equipment

Optional on Request

  • Copper-free aluminium or SS316L Exd enclosures
  • Protective coatings to enhance corrosion resistance in harsh conditions
  • Power distribution
  • System by-pass

The product picture is for reference only and includes the optional power distribution and system by-pass. An example drawing with dimensions is shown in the product gallery and in the datasheet.


Why Choose EXCEN UPS from Daly Middle East?

  • Manufactured in Italy with ATEX and IECEx certification for Zone 1, 2, 21 and 22
  • Ready-to-install system complete with certified battery and dedicated battery breaker
  • Fast transfer time (≤ 15 ms) and pure sine wave output
  • Customized power and input/output ratings available on request
  • GCC-wide availability with local support from Daly Middle East in Dubai, Qatar, Oman and Saudi Arabia

Contact Daly Middle East for the technical datasheet, pricing and project-specific UPS solutions. Our team can support you from specification through to delivery across the GCC.

Built for the job

Key features

Manufactured in Italy, ATEX and IECEx certified for Zone 1, 2, 21 and 22

Standard configuration up to 6 kVA (see thermal derating table)

Fast transfer time of 15 ms or less with pure sine wave output

IP66 rating and wide ambient temperature range

Modular design on a robust frame with glass inspection window for status and alarms

Ready-to-install with ATEX & IECEx certified stainless steel battery (AGM, GEL or NiCd)

Dedicated battery breaker between UPS and battery for safety and easy maintenance

Options: Exd enclosures in copper-free aluminium or SS316L, protective coatings, power distribution, system by-pass

Standard PowerUp to 6 kVA
Input150-265 Vac / 50-140 Vac, 45-65 Hz
OutputPure sine wave 230 Vac (±2%) / 120 Vac
Output Frequency50 Hz ±0.05%, 45-65 Hz programmable
Transfer Time≤ 15 ms
ProtectionIP66
BatteryAGM, GEL or NiCd, ATEX & IECEx certified, SS enclosure
CertificationATEX & IECEx, Zone 1, 2, 21, 22
Documentation

Manufacturer datasheet

Full technical and certification data as published by Excen.

EXCEN-Tech-Data-Sheet-UPS_ENG.pdfPDF
Product FAQ

Frequently asked

What hazardous area zones is the EXCEN NRG 3K UPS certified for?
It is ATEX and IECEx certified for Zone 1, Zone 2, Zone 21 and Zone 22.
What power rating does the NRG 3K UPS support?
The standard configuration supports up to 6 kVA, subject to the thermal derating table. Custom power and input/output ratings are available on request.
How fast is the transfer to battery?
Transfer time is 15 ms or less.
Is the battery included?
Yes. The system is supplied ready to install with an ATEX & IECEx certified battery in a stainless steel enclosure (AGM, GEL or NiCd), plus a dedicated battery breaker.
How long can the UPS run on battery?
With a 48 VDC, 205 Ah battery bank at 25°C, backup time ranges from 15 hours at 500 VA to 45 minutes at 6,000 VA. Actual time varies with battery age, temperature and efficiency.
What are the typical applications?
Oil & Gas facilities, chemical and petrochemical plants, refineries, emergency shutdown systems, fire & gas detection, power distribution and automation, and other safety-critical equipment.