Good visibility is not a convenience in hazardous area work, it is a safety requirement. Poor lighting inside a tank, vessel, or confined space slows work down and increases the chance of mistakes, while uncertified lighting introduces the exact ignition risk that hazardous area regulations are designed to prevent. The Ex LED worklight solves both problems at once.
What Is the Ex LED Worklight 200?
The Ex LED Worklight 200 is a lightweight, high-output work light certified for Zone 1 and Zone 2 gas atmospheres and Zone 21 and Zone 22 dust atmospheres. It delivers a genuinely bright 5,700 lumens of 360° illumination, so crews can see clearly in every direction without repositioning the light. Standard work lights are not built to prevent sparking, excessive heat build-up, or ingress of flammable gas and dust into their electrical components — the light is engineered from the ground up to eliminate that risk.
Key Features of the Ex LED Worklight
- 5,700 lumens of 360° light output (8,000 lumens at source), for genuinely usable full-coverage illumination
- High Power LED technology rated for a 50,000-hour lifespan
- Lightweight at just 2.7kg, easy to carry, hang, or mount
- Linkable versions available, so multiple lights can be daisy-chained along a single circuit
- IP66 rated for full waterproof and dustproof protection
- Enhanced cable gland and socket protection for long-term durability in the field
- Supplied with adjustable hanging straps and protective film, with an optional Vessel Entry Kit
Certifications
The light is certified under ATEX and IECEx for Zone 1 and Zone 2 gas atmospheres, and Zone 21 and Zone 22 dust atmospheres, with INMETRO and UKCA certification also in place. Full specification data is published on the manufacturer’s official Ex LED Worklight 200 product page.
Ex LED Worklight Technical Specifications
| Light Output | 5,700 lumens (360°) / 8,000 lumens at source |
| Voltage Options | 12, 24, 42, 110, 230 VAC/DC |
| Operating Temperature | -20°C to +55°C |
| Ingress Protection | IP66 |
| Weight | 2.7kg |
| Certification | ATEX, IECEx, INMETRO, UKCA — Zones 1, 2, 21 & 22 |
Where the Ex LED Worklight Is Used
- Fuel tank and vessel entry work
- Aircraft maintenance
- Oil refineries and chemical plants
- Confined space work and pipeline maintenance
- Offshore platform operations
Why Choose the Ex LED Worklight from Daly Middle East
Daly Middle East stocks the light locally for the UAE and GCC, alongside a wider range of portable ATEX lighting including torches, handlamps, and headlamps. Browse the full portable worklights range to compare models for your site.
How to Choose the Right Ex LED Worklight for Your Site
Start with voltage compatibility — the light is available across 12, 24, 42, 110, and 230 VAC/DC options, so match it to the power distribution equipment already on site, such as an Ex transformer or splitter box. Next, think about coverage. A single worklight delivers 5,700 lumens of 360° illumination, which suits most confined spaces, but longer tanks, vessels, or corridors may need two or more linked units to avoid dark spots at either end of the run.
If you expect to light an extended area, the linkable version is worth specifying up front — it allows multiple lights to be daisy-chained on a single circuit using the 5m linkable cable, reducing the number of separate power drops you need to run. For vessel entry work specifically, the optional Vessel Entry Kit adds mounting accessories designed for that use case, so check whether your job calls for it before ordering.
Renting vs Buying an Ex LED Worklight in the UAE and GCC
Because lighting needs often scale up and down with project size, many contractors hire additional units through Daly Middle East during larger shutdowns and turnarounds, while keeping a smaller core set owned outright for day-to-day confined space work. With a 50,000-hour LED lifespan, units that are purchased tend to deliver strong value over time for teams with regular hazardous area lighting needs.
Safety Checks Before Every Deployment
Before hanging or mounting any portable light in a classified area, confirm the certification label matches your site’s zone classification, check the cable gland and lens for cracks or damage, and confirm hanging straps are securely fastened before entering a confined space. Good lighting is only a safety benefit if the fitting itself is in sound condition, so a quick pre-use inspection is worth the extra minute, particularly for units that see frequent handling between projects.
Daly Middle East’s technical support team can advise on inspection intervals and safe configuration for hired and purchased lighting equipment alike.
Ex LED Worklight FAQs
How bright is the light?
It delivers 5,700 lumens of 360° light output, with 8,000 lumens measured at the light source, giving strong, even illumination across a confined space.
Can multiple lights be connected together?
Yes. The linkable version allows multiple worklights to be daisy-chained on a single circuit using the 5m linkable cable option.
What zones is the light certified for?
It is certified under ATEX and IECEx for Zone 1 and Zone 2 gas atmospheres, and Zone 21 and Zone 22 dust atmospheres.
How long do the LEDs last in the light?
The high-power LEDs are rated for a 50,000-hour operational lifespan, reducing replacement frequency and long-term running costs.
Can I hire the light for a single project?
Yes. Daly Middle East offers hire options for the light alongside outright purchase, suiting both short-term and ongoing lighting needs.
Is a Vessel Entry Kit available for the light?
Yes. An optional Vessel Entry Kit is available with mounting accessories designed specifically for tank and vessel entry work.
Need certified lighting for your next confined space job? Contact Daly Middle East for stock availability and a tailored quote.