Home / Applications / Temporary and shutdown lighting

Application guide

Temporary & Shutdown Lighting for Hazardous Areas in the UAE & GCC

Turnarounds and tank entries need light fast, in the right place and safe to use. We supply portable Ex worklights, floodlights, area lights and intrinsically safe lamps for Zone 1 and Zone 2 work.

Zone 1 and Zone 2Gas, with dust Zones 21 and 22 on SA Lumin
Up to 30,000 lmArea lights for big work fronts
Cordless optionRechargeable floodlight for tank entry
Intrinsically safeZone 0 angle and scene lights

Which portable light suits the job?

Choose by the size of the space, whether cables are allowed, and the hazardous-area zone.

Your situation Start with Why
Tight spaces and hand-carried tasks SA Lumin Worklight 100 1.8 kg and under 29 W. Certified for Zones 1 and 2 (gas) and 21 and 22 (dust).
A vessel or room that needs light all round SA Lumin Worklight 200 4,000 lm with 360 degree distribution, certified for the same zones.
A wide work area or tank bund SA Lumin Floodlight SAFL300 Over 8,000 lm, with an operating range of -50 to +55 °C.
Confined space entry where cables are a hazard SA Lumin Rechargeable Floodlight SARF300 Cordless with up to 2,000 lm, so there are no trailing cables.
Large work fronts during a turnaround SA Lumin EX Area Light 30,000 lm from 300 W, Ex certified for Zones 1 and 2 (gas), with a scaffold clamp.
A big area on a 42 V supply Ex Floodlight RFID Up to 20,000 lm from 230 VAC or 42 VAC, with an RFID tag in the housing for inspection records.
Inspection, rescue or hand-held work in Zone 0 Intrinsically safe angle light or scene light The Intrant Duo Turbo is certified for ATEX Zone 0/20. The Nightstick XPR-5592GX is a Zone 0 intrinsically safe scene light.

Temporary lights need a power source that is also safe. Portable ATEX transformers and distribution boxes supply 110 V or 42 V to many of these lights, so plan the power with the lighting.

Portable and temporary lighting we supply

Every item below links to its product page. Specifications are taken from the product pages, so check the datasheet for your exact model and approval.

SA Lumin EX LED Worklight 100
Worklight

SA Lumin Worklight 100

Compact 1.8 kg worklight drawing under 29 W. Zones 1 and 2 (gas), 21 and 22 (dust).

View product

SA Lumin EX LED Worklight 200
360 degree worklight

SA Lumin Worklight 200

4,000 lm with full 360 degree distribution. Same zone certification.

View product

SA Lumin EX LED Floodlight SAFL300
Floodlight

SA Lumin Floodlight SAFL300

Over 8,000 lm, -50 to +55 °C. Zones 1 and 2 (gas), 21 and 22 (dust).

View product

SA Lumin EX rechargeable floodlight SARF300
Cordless floodlight

SA Lumin Rechargeable Floodlight

Up to 2,000 lm with no mains cable, for confined space entry.

View product

SA Lumin EX 30,000 lumen LED area light
Area light

SA Lumin EX Area Light

30,000 lm from 300 W. Ex certified for Zones 1 and 2 (gas). Scaffold clamp.

View product

Ex floodlight RFID
Floodlight, 20,000 lm

Ex Floodlight RFID

Up to 20,000 lm on 230 VAC or 42 VAC, RFID tag and Gorilla glass.

View product

Nightstick XPR-5592GX Zone 0 intrinsically safe scene light
Scene light, Zone 0

Nightstick XPR-5592GX Scene Light

Zone 0 intrinsically safe scene light for hazardous-area work.

View product

Nightstick Intrant Duo Turbo intrinsically safe angle light
Angle light, Zone 0/20

Nightstick Intrant Duo Turbo

ATEX Zone 0/20, cETLus and IECEx. 250 or 110 lm spot with a 469 m beam.

View product

Power the lights safely with SA Powernet EX 400VA transformers and EX splitter boxes. Browse Portable ATEX Lights.

How to plan temporary lighting for a shutdown

Six points to settle before the crews arrive.

  1. What zones will the crews work in?Give the zone, gas and dust group and temperature class for every work front.
  2. How much light does each task need?Detailed inspection needs more light than general access. Match lumens to the task and area.
  3. Can cables be used?In confined spaces, cordless lights remove the trip and damage risk.
  4. How is the lighting powered?Plan Ex-rated transformers and distribution so lights are powered safely and from the correct voltage.
  5. How will lights be mounted?Free-standing, clamped to scaffold or magnetic bases each suit different positions.
  6. How will you track inspection?Some fixtures carry RFID tags that make maintenance and inspection records easier.

Where these systems are used

Plant shutdowns and turnarounds

Area lights and floodlights across many work fronts at once.

Tank and vessel entry

Cordless floodlights and compact worklights inside the space.

Inspection and maintenance rounds

Intrinsically safe angle and hand lights for technicians.

Emergency response and rescue

Zone 0/20 certified lights for fire and rescue crews.

Brands behind these products

Temporary and shutdown lighting FAQs

What is the difference between a worklight and a floodlight?

A worklight lights a close task or a small space, often 360 degrees. A floodlight lights a wider area from a stand. Both come in Ex certified versions for hazardous areas.

Can I use cordless lights in confined spaces?

Yes, if they are certified for the zone. The SA Lumin rechargeable floodlight has no mains cable and gives up to 2,000 lm.

Which portable lights are certified for Zone 1?

The SA Lumin worklights and floodlights are certified for Zones 1 and 2 (gas) and 21 and 22 (dust). The SA Lumin EX Area Light is Ex certified for Zones 1 and 2 (gas).

Do portable lights need special power supply?

Many run from 110 V or 42 V supplied by an Ex-rated transformer. SA Powernet EX transformers and splitter boxes are available for this.

Do you supply lights for Zone 0?

Yes. The Intrant Duo Turbo angle light is certified for ATEX Zone 0/20 and the Nightstick XPR-5592GX is a Zone 0 intrinsically safe scene light.

Do you supply temporary lighting across the GCC?

Yes. Daly Middle East supplies from Dubai to the UAE, Saudi Arabia, Oman, Qatar, Kuwait and Bahrain.

Planning a shutdown or turnaround in the UAE or GCC?

Send us the zones, work areas, light levels and power available. We will recommend the lighting and quote it.

Request a quote